Recessed
FIRI-05-418 Rigips (SP;DP;DR)
Recessed luminaire for plasterboard ceilings.
- Steel sheet body white painted with powder in which the electric gear is mounted.
- Flat V shaped reflector (DR) made from aluminium sheet with a reflection factor >0.85, special designed to obtain low luminances.
- Simple safety suspension RI (interior adjustment 0.7÷1.4m).
- Gear (ballast) included in the product and manufactured according to the specific standards.
- Colour: white.
Application
General indoor lighting for rooms with plasterboard false ceiling. Public buildings, commercial areas, schools. Lighting for offices with computer monitors.
Light source
- Tubular fluorescent lamps T8 (ø26mm) G13.
Compliance
Choose model
Name | FIRI-05-418 DR Rigips |
---|---|
Assembly type | Recessed in the ceiling |
Types of gear | Adjustable, Efficient, Electromagnetic ballast, Electronical ballast, Standard |
Light distribution | Direct distribution |
Type of lamp | Fluorescent lamps, T8 Ø26 (G13) |
Power | from 20 to 100 |
Number of sources | 4 |
Level of protection | IP40 |
Options for emergency light | 1 hour, 3 hours |
Rated power [W] | 4×18 |
---|---|
Power factor cos φ  | ≥0.92 |
Class of protection against electric shock | I |
Weight [Kg] | ~4,44 |

Product type | L (mm) | m (mm) | l (mm) | H (mm) | n (mm) |
---|---|---|---|---|---|
FIRI-05-418 Rigips | 630 | 590 | 605 | 80 | 590 |
Technical features
- Rated voltage: 230V/50Hz
- Surrounding temperature: -5 ̊C…+ 35 ̊C
- Relative humidity: till 80% at the temperature of + 20 ̊C
- Saline fog: 48 hours according to SR EN 60068-2-11
- Jolt resistance: 1000±10jolts, acceleration of 10g, duration of impulse: 16ms, according to SR EN 60068-2-29.
- The luminaire is manufactured according to the requirements of the luminaire standards SR EN 60598-1, SR EN 60598-2-2.
Variants on request
- On request the variant with fluorescent tubes could be equipped with:
- standard electronic ballast HFS.
- high performance electronic ballast HFP.
- dimmable electronic ballast HFR.
- Double parabolic reflector (DP) or simple parabolic reflector (SP) made from aluminium sheet with a reflection factor >0.85.
- On request variant for 36W fluorescent tubes T8 (4x36W for cut-out dimensions 1190x590mm).
- Note. The options could be combined function of the customer request.
Mounting
- Recessed in plasterboard ceilings with the cut-out dimension 590×590 mm.
Compliance with the European Directives
- Low Voltage Directive
- Electromagnetic Compatibility Directive
- RoHS Directive, WEEE Directive
Photometric data FIRI-05-418 DR7L Rigips
CIE: 62 93 99 100 62
UTE: 0.62C
UGR < 19
Light distribution diagram [Cd/1000lm]
Name | FIRI-05-418 DP Rigips |
---|---|
Assembly type | Recessed in the ceiling |
Types of gear | Adjustable, Efficient, Electromagnetic ballast, Electronical ballast, Standard |
Light distribution | Direct distribution |
Type of lamp | Fluorescent lamps, T8 Ø26 (G13) |
Power | from 20 to 100 |
Number of sources | 4 |
Level of protection | IP40 |
Options for emergency light | 1 hour, 3 hours |
Rated power [W] | 4×18 |
---|---|
Power factor cos φ  | ≥0.92 |
Class of protection against electric shock | I |
Weight [Kg] | ~4,44 |

Product type | L (mm) | m (mm) | l (mm) | H (mm) | n (mm) |
---|---|---|---|---|---|
FIRI-05-418 Rigips | 630 | 590 | 605 | 80 | 590 |
Technical features
- Rated voltage: 230V/50Hz
- Surrounding temperature: -5 ̊C…+ 35 ̊C
- Relative humidity: till 80% at the temperature of + 20 ̊C
- Saline fog: 48 hours according to SR EN 60068-2-11
- Jolt resistance: 1000±10jolts, acceleration of 10g, duration of impulse: 16ms, according to SR EN 60068-2-29.
- The luminaire is manufactured according to the requirements of the luminaire standards SR EN 60598-1, SR EN 60598-2-2.
Variants on request
- On request the variant with fluorescent tubes could be equipped with:
- standard electronic ballast HFS.
- high performance electronic ballast HFP.
- dimmable electronic ballast HFR.
- Double parabolic reflector (DP) or simple parabolic reflector (SP) made from aluminium sheet with a reflection factor >0.85.
- On request variant for 36W fluorescent tubes T8 (4x36W for cut-out dimensions 1190x590mm).
- Note. The options could be combined function of the customer request.
Mounting
- Recessed in plasterboard ceilings with the cut-out dimension 590×590 mm.
Compliance with the European Directives
- Low Voltage Directive
- Electromagnetic Compatibility Directive
- RoHS Directive, WEEE Directive
Photometric data FIRI-05-418 DR7L Rigips
CIE: 62 93 99 100 62
UTE: 0.62C
UGR < 19
Light distribution diagram [Cd/1000lm]
Name | FIRI-05-418 SP Rigips |
---|---|
Assembly type | Recessed in the ceiling |
Types of gear | Adjustable, Efficient, Electromagnetic ballast, Electronical ballast, Standard |
Light distribution | Direct distribution |
Type of lamp | Fluorescent lamps, T8 Ø26 (G13) |
Power | from 20 to 100 |
Number of sources | 4 |
Level of protection | IP40 |
Options for emergency light | 1 hour, 3 hours |
Rated power [W] | 4×18 |
---|---|
Power factor cos φ  | ≥0.92 |
Class of protection against electric shock | I |
Weight [Kg] | ~4,44 |

Product type | L (mm) | m (mm) | l (mm) | H (mm) | n (mm) |
---|---|---|---|---|---|
FIRI-05-418 Rigips | 630 | 590 | 605 | 80 | 590 |
Technical features
- Rated voltage: 230V/50Hz
- Surrounding temperature: -5 ̊C…+ 35 ̊C
- Relative humidity: till 80% at the temperature of + 20 ̊C
- Saline fog: 48 hours according to SR EN 60068-2-11
- Jolt resistance: 1000±10jolts, acceleration of 10g, duration of impulse: 16ms, according to SR EN 60068-2-29.
- The luminaire is manufactured according to the requirements of the luminaire standards SR EN 60598-1, SR EN 60598-2-2.
Variants on request
- On request the variant with fluorescent tubes could be equipped with:
- standard electronic ballast HFS.
- high performance electronic ballast HFP.
- dimmable electronic ballast HFR.
- Double parabolic reflector (DP) or simple parabolic reflector (SP) made from aluminium sheet with a reflection factor >0.85.
- On request variant for 36W fluorescent tubes T8 (4x36W for cut-out dimensions 1190x590mm).
- Note. The options could be combined function of the customer request.
Mounting
- Recessed in plasterboard ceilings with the cut-out dimension 590×590 mm.
Compliance with the European Directives
- Low Voltage Directive
- Electromagnetic Compatibility Directive
- RoHS Directive, WEEE Directive
Photometric data FIRI-05-418 DR7L Rigips
CIE: 62 93 99 100 62
UTE: 0.62C
UGR < 19
Light distribution diagram [Cd/1000lm]