Recessed
FIRI-07-414/424 DP Platos
High lighting output ratio luminaire, designed for general indoor lighting that offers different variants for lighting with low brightness.
The luminaire FIRI-07 Platos has a low height housing made of steel sheet white painted with powder and a double parabolic reflector made of mirrored aluminium sheet.
It will be mounted in modular recessed ceilings. As light sources there are used fluorescent T5 tubes.
- Steel sheet body white painted with powder in which the electric gear is mounted.
- Double parabolic reflector (DP) made from aluminium sheet with a reflection factor >0.85
- Gear (ballast) included in the product and manufactured according to the specific standards.
- Colour: white.
Application
General indoor lighting. Public buildings, commercial areas, schools. Lighting for offices with computer monitors. Emergency lighting for evacuation with one fluorescent tube.
Light source
- Tubular fluorescent lamps T5 (ø16mm) G5.
Compliance
Name | FIRI-07-414 DP |
---|---|
Assembly type | Recessed in the ceiling |
Types of gear | Adjustable, Efficient, Electronical ballast, Standard |
Light distribution | Direct distribution |
Type of lamp | Fluorescent lamps, T5 Ø16 (G5) |
Power | from 20 to 100 |
Number of sources | 4 |
Level of protection | IP40 |
Options for emergency light | 1 hour |
Rated power [W] | 4×14 |
---|---|
Power factor cos φ  | ≥0.95 |
Class of protection against electric shock | I |
Weight [Kg] | 4,70 |

Product type | L (mm) | m (mm) | l (mm) | H (mm) | n (mm) |
---|---|---|---|---|---|
FIRI-07-414/424 DP Platos | 595 | 600 | 595 | 60 | 600 |
Technical features
- Rated voltage: 230V/50Hz
- Surrounding temperature: -5 ̊C…+ 35 ̊C
- Relative humidity: till 80% at the temperature of + 20 ̊C
- Saline fog: 48 hours according to SR EN 60068-2-11
- Jolt resistance: 1000±10jolts, acceleration of 10g, duration of impulse: 16ms, according to SR EN 60068-2-29.
- The luminaire is manufactured according to the requirements of the luminaire standards SR EN 60598-1, SR EN 60598-2-2.
Variants on request
- On request the product could be equipped with:
- o standard electronic ballast HFS.
- o dimmable electronic ballast HFR 1-10V.
- o reflector with reduced number of transversal lamellae (FIRI-07-414 E DP 12L).
Mounting
- Recessed in modular ceilings with the module dimension 600×600 mm.
Compliance with the European Directives
- Low Voltage Directive
- Electromagnetic Compatibility Directive
- RoHS Directive, WEEE Directive
Photometric data FIRI-07-414 DP Platos
CIE:69 97 100 99 69
UTE: 0.69C
UGR < 16
Light distribution diagram [Cd/1000lm]
Name | FIRI-07-424 DP |
---|---|
Assembly type | Recessed in the ceiling |
Types of gear | Adjustable, Efficient, Electronical ballast, Standard |
Light distribution | Direct distribution |
Type of lamp | Fluorescent lamps, T5 Ø16 (G5) |
Power | from 20 to 100 |
Number of sources | 4 |
Level of protection | IP40 |
Options for emergency light | 1 hour |
Rated power [W] | 4×24 |
---|---|
Power factor cos φ  | ≥0.95 |
Class of protection against electric shock | I |
Weight [Kg] | 5,10 |

Product type | L (mm) | m (mm) | l (mm) | H (mm) | n (mm) |
---|---|---|---|---|---|
FIRI-07-414/424 DP Platos | 595 | 600 | 595 | 60 | 600 |
Technical features
- Rated voltage: 230V/50Hz
- Surrounding temperature: -5 ̊C…+ 35 ̊C
- Relative humidity: till 80% at the temperature of + 20 ̊C
- Saline fog: 48 hours according to SR EN 60068-2-11
- Jolt resistance: 1000±10jolts, acceleration of 10g, duration of impulse: 16ms, according to SR EN 60068-2-29.
- The luminaire is manufactured according to the requirements of the luminaire standards SR EN 60598-1, SR EN 60598-2-2.
Variants on request
- On request the product could be equipped with:
- o standard electronic ballast HFS.
- o dimmable electronic ballast HFR 1-10V.
- o reflector with reduced number of transversal lamellae (FIRI-07-414 E DP 12L).
Mounting
- Recessed in modular ceilings with the module dimension 600×600 mm.
Compliance with the European Directives
- Low Voltage Directive
- Electromagnetic Compatibility Directive
- RoHS Directive, WEEE Directive
Photometric data FIRI-07-414 DP Platos
CIE: 69 97 100 99 69
UTE: 0.69C
UGR < 16
Light distribution diagram [Cd/1000lm]
Name | FIRI-07-414 E DP 12L |
---|---|
Assembly type | Recessed in the ceiling |
Types of gear | Adjustable, Efficient, Electronical ballast, Standard |
Light distribution | Direct distribution |
Type of lamp | Fluorescent lamps, T5 Ø16 (G5) |
Power | from 20 to 100 |
Number of sources | 4 |
Level of protection | IP40 |
Options for emergency light | 1 hour |
Rated power [W] | 4×14 |
---|---|
Power factor cos φ  | ≥0.95 |
Class of protection against electric shock | I |
Weight [Kg] | 4,50 |

Product type | L (mm) | m (mm) | l (mm) | H (mm) | n (mm) |
---|---|---|---|---|---|
FIRI-07-414/424 DP Platos | 595 | 600 | 595 | 60 | 600 |
Technical features
- Rated voltage: 230V/50Hz
- Surrounding temperature: -5 ̊C…+ 35 ̊C
- Relative humidity: till 80% at the temperature of + 20 ̊C
- Saline fog: 48 hours according to SR EN 60068-2-11
- Jolt resistance: 1000±10jolts, acceleration of 10g, duration of impulse: 16ms, according to SR EN 60068-2-29.
- The luminaire is manufactured according to the requirements of the luminaire standards SR EN 60598-1, SR EN 60598-2-2.
Variants on request
- On request the product could be equipped with:
- o standard electronic ballast HFS.
- o dimmable electronic ballast HFR 1-10V.
- o reflector with reduced number of transversal lamellae (FIRI-07-414 E DP 12L).
Mounting
- Recessed in modular ceilings with the module dimension 600×600 mm.
Compliance with the European Directives
- Low Voltage Directive
- Electromagnetic Compatibility Directive
- RoHS Directive, WEEE Directive
Photometric data FIRI-07-414 DP Platos
CIE: 69 97 100 99 69
UTE: 0.69C
UGR < 16
Light distribution diagram [Cd/1000lm]